PROBLEMS
7) Lock opens intermittently
when using valid codes
8) Lock beeps three times when
code is entered, but doesnʼt
open
9) Unable to delete time delay
10) Unable to set time delay for
more than nine minutes or to
adjust opening window on model
6123 lock
11) After entering the code for a
spring bolt lock, the motor starts,
but the safe door cannot be
opened
12) Lock motor runs continuously
after a battery change, and the
lock stays locked
13) Lock opens okay, but bolt will
not re-extend far enough to lock
safe.
POSSIBLE CAUSE
Connection of wires to back
of keypad is loose
Keypad is bad
Lock is in time delay mode
Time delay can only be
deleted during the opening
window
You are using the Supervisor
code (model 6123 only) or
a User Code (either model)
instead of the Master Code
Lock may be model 6120
Bolt of the lock is binding
against the door frame or
door strike
The logic circuit did not reset
properly when power was
restored to the logic circuits
Batteries are weak
POSSIBLE SOLUTION(S)
Perform Keypad Connector
Check (#8)
Replace with new keypad
Wait for time delay to expire,
then delete time delay—see
lock operating instructions or
consult toll free help line
Wait for opening window
before attempting to delete
time delay—see lock operat-
ing instructions or consult toll
free help line
The Master Code must be
used to delete the time delay.
Perform Master Code Check
Procedure (#3)—see lock
operating instructions or con-
sult toll free help line
Perform Model Check
Procedure (#9)—see lock
operating instructions or con-
sult toll free help line
Push in on the door while
entering the code; remove the
source of the binding after the
door is open
Perform Walk Back Procedure
(#5)
Unplug the wire connector
from the back of the keypad,
leave it unplugged for at least
30 seconds, then plug it back
into the receptacle on the
back of the keypad. The pro-
cessor should reset properly.
See Battery Check and
Replacement Procedure (#6)
Vedere la pagina 2